WRINKLES

& FINE LINES

MEDICAL MICRONEEDLING WITH EXCEED AND EXCEED UNLIMITED

A clinical guide to facial rhytides, skin texture and laxity: patient selection, the published treatment approach and measured outcomes.

Clinically Proven

Published platform evidence

German Engineering

Built to exceptional standards

10-Year Full Warranty

Long-term investment protection

Evidence

ISO 13485-Certified

quality management system

73%visible lines/wrinkles and texture improvement
83%visible pore improvement
1.23 gradesglobal wrinkles improvement
1.54 gradesskin texture improvement
Clinical procedure VIDEO

Medical Microneedling for Wrinkles & Skin Rejuvenation

Patient selection, needle depth, treatment techniques and clinical endpoints.

Expert demonstration

See skin rejuvenation in practice.

PD Dr. med. Matthias Aust demonstrates medical microneedling for wrinkles, fine lines, and skin rejuvenation, addressing treatment expectations, skin quality goals, differences from injectables, and the underlying biological wound-healing processes.

Who benefits from medical microneedling?

Understand how microneedling addresses skin texture, enlarged pores and overall skin quality, and where its limitations lie.

How do you optimize treatment techniques?

Explore needle depth adjustments from 1.0 to 1.5 mm, continuous movements and safe techniques around delicate facial areas.

When is the clinical endpoint reached?

See how pinpoint bleeding guides needle depth, pressure and treatment coverage while helping avoid unnecessary skin trauma.

Complete the form to watch the expert video.

Expert video

Watch the clinical procedure video

Complete the form to access the video.

Clinical evidence · Study overview

Facial wrinkles, texture and laxity: the evidence at a glance.

Facial wrinkles before treatment; illustrative clinical photograph
Facial wrinkles after treatment; illustrative clinical photograph
Before treatment
After treatment
BeforeAfter
EU OFF-LABELAblon 2018 · 48 participants

The EXCEED family: a studied platform

A structured four-session course was associated with improvements in facial ageing signs in Exceed study.

The study evaluated nine facial wrinkle regions, skin texture and laxity. The images alongside are separate illustrative cases from amiea med, not photographs identified as study participants.

Study schedule [1]

4treatments
30 daysbetween sessions
Day 150final assessment

Mean grade improvement at Day 150 [1]

1.23global wrinkles
1.54skin texture
1.09skin laxity
Study interpretation and photography

This was an open-label, single-centre study without a control group. The results do not establish identical outcomes for every EXCEED family member. Photographs are illustrative individual cases; their treatment counts and follow-up intervals are not supplied. Read the full clinical pathway and reference [1] below.

Periorbital images: courtesy of amiea med. Lower-face images: courtesy of Dr. Dorota Kowalczyk, MD; source reports use of exosomes from probiotic bacteria. These photographs are separate from the Ablon study.

Clinical evidence · Assessment

Define the concern. Establish the baseline.

Study population [1]

Who was studied?

48 adults completed all four sessions and follow-up visits.

Eligibility covered healthy adults aged 35–75 years with facial rhytides graded 1–4 on the Lemperle scale and laxity graded 1–3.5 on the Alexiades-Armenakas scale.

39–67actual age range
I–Vobserved Fitzpatrick types
Understand the evidence population

Mean age was 55.1 years; participants were predominantly women and the mean phototype was 2.2. These findings do not establish equal efficacy in every phototype or age group. The single-centre, open-label study had no control group.

Wrinkle assessment [1]

Map all nine facial regions

Use regional grading alongside an overall facial score.

The investigator graded horizontal forehead lines, glabellar frown lines, periorbital lines, preauricular lines, cheek folds, nasolabial folds, upper lip lines, marionette lines and the labiomental crease.

9regional wrinkle scores
1global mean score
What the paper does and does not classify

The Lemperle photonumeric scale was selected for reproducibility and its relationship to profilometric wrinkle depth. The paper does not define separate diagnostic algorithms or treatment regimens for static versus dynamic wrinkles. Its global score is the mean of all nine regional grades.

Skin quality [1]

Separate texture, laxity and patient perception

Fine lines are one part of the ageing-skin assessment.

The physician assessed laxity and texture with a modified Alexiades-Armenakas scale. Patients separately rated pigmentation, lines and wrinkles, texture and pores on a 0–4 scale.

0–4patient self-rating
VISIAclinical photography
Set measurable goals

In the patient scale, 0 represented the most favourable appearance or feel and 4 the least favourable. Pigmentation and pores were subjective outcomes; the paper does not establish a diagnosis-specific regimen for melasma or enlarged pores. Do not equate patient ratings with physician grading.

Study screening [1]

Check the exclusion criteria

The reported outcomes apply to a screened study population.

Exclusions included anticoagulants, aspirin or high-dose NSAIDs within the previous 14 days; hepatitis; active facial acne; inflammatory skin conditions; uncontrolled diabetes; keloid scars; HPV; birth marks; eczema; known malignancy; chemotherapy, radiotherapy or high-dose corticosteroids.

3 monthsexclusion window for fillers or neuromodulators
Allergies and medical history

Known allergy to the topical anaesthetic was also an exclusion. These are study criteria, not instructions to discontinue prescribed medication. The paper recorded herpes labialis outbreaks, making this history relevant to counselling. Current device instructions and individual medical assessment remain necessary.

Clinical evidence · Published procedure

A four-session course, adapted by facial zone.

Schedule [1]

Plan the series and the delayed review

Treatments took place on Days 0, 30, 60 and 90.

Assessments were performed at baseline and before the subsequent sessions on Days 30, 60 and 90. The final assessment was on Day 150, approximately 60 days after the fourth treatment.

4sessions
30 daysbetween sessions
Day 150final review
Discuss the full timeline

The study documented further improvement between Days 90 and 150. It did not test a maintenance schedule or establish durability beyond Day 150. This page reports the study approach; it is not a universal treatment prescription.

Preparation [1]

Cleanse, anaesthetise and prepare the surface

The publication describes a specific preparation sequence.

After cleansing, LMX 4 topical anaesthetic was applied to the face and jawline. After 30 minutes it was removed with a cotton pad soaked in 70% isopropyl alcohol, and the skin was allowed to dry.

30 minanaesthetic exposure in the study
Sterile gelused for cartridge glide
Products used in the study

Sterile Clear Image singles gel was applied liberally to assist movement. These are reported study products and methods, not a recommendation to substitute products or override current labelling, eye-area precautions or the device instructions. No PRP, exosome or active-serum combination was evaluated in this trial.

Delivery [1]

Circular movement with an observed endpoint

The study adjusted depth to achieve pinpoint bleeding.

The cartridge was moved in circular motions across the face. The studied configuration used six sterile, single-use stainless-steel needles, depth adjustment from 0 to 1.5 mm and a device frequency range of 100–150 Hz.

6needles in the study cartridge
0–1.5 mmadjustment range
Do not invent missing settings

The paper does not report one fixed treatment frequency, pass count, pressure, movement speed or whole-face procedure duration. Its 100–150 Hz value describes the device range, not a proven wrinkle-specific setting. More intense bleeding was not a stated treatment goal.

Immediate aftercare [1]

Cleanse and support recovery

Post-treatment care included moisturiser and sun block.

After treatment, the skin was cleansed with warm water and sterile gauze. Participants received post-skin-care instructions including moisturiser and sun block, and kept symptom diaries for up to seven days.

7 dayspost-treatment symptom diary
Keep aftercare claims within the evidence

The publication does not specify an SPF value, a named moisturiser, a make-up restart time or a full day-by-day skincare regimen. It reports the above measures without comparing alternative aftercare programmes.

Clinical evidence · Zone-specific settings

Reported depths and regional wrinkle outcomes.

Upper face [1]

Forehead and glabella

Two regions, two reported depth ranges.

Forehead: 0.7–1.0 mm. Glabella: 0.7–1.3 mm. Mean wrinkle-grade improvement at Day 150 was 1.1 for horizontal forehead lines and 1.6 for glabellar frown lines.

1.1 gradesforehead
1.6 gradesglabella
Read the regional response

Mean baseline grades were 2.6 and 3.2, respectively; Day 150 grades were 1.5 and 1.6. The paper reports region-level outcomes, not separate results for muscle-driven and static line subtypes. Values are means, not guaranteed individual improvements.

Eye area [1]

Periorbital lines

The eye-area range was shallower than the cheek range.

The study used 0.5–0.8 mm for the eye area. Mean periorbital wrinkle grade fell from 3.3 at baseline to 1.4 at Day 150, with a reported mean improvement of 1.9 grades.

0.5–0.8 mmreported eye-area depth
1.9 gradesmean improvement
Objective surface assessment

PRIMOS periorbital measurements at Day 150 showed reductions of 26% in mean surface roughness (Sa) and 30% in average line roughness (Ra). These are distinct topographic parameters, not a percentage reduction in every wrinkle. The paper provides no detailed eyelid technique.

Midface [1]

Cheek folds and deeper facial folds

Regional responses differed despite the same overall course.

Cheek depth was 0.9–1.5 mm. At Day 150 the reported mean improvement was 1.8 grades for cheek folds, compared with 0.6 for nasolabial folds and 0.4 for preauricular lines.

1.8 gradescheek folds
0.6 gradesnasolabial folds
0.4 gradespreauricular lines
Set region-specific expectations

The study does not specify additional independent depth ranges for nasolabial folds or preauricular lines. It does not test deeper needling or another treatment to overcome their smaller average response. Do not promise that every facial fold will respond like cheek folds.

Lower face [1]

Upper lip, chin and jawline

Use the published anatomical ranges without inventing extra protocols.

Upper lip: 0.7–1.0 mm; chin: 0.9–1.3 mm; jawline: 0.7–1.3 mm. Mean improvement at Day 150 was 1.9 grades for upper lip lines, 1.1 for the labiomental crease and 0.7 for marionette lines.

1.9 gradesupper lip
1.1 gradeslabiomental crease
0.7 gradesmarionette lines
Counselling around the mouth

Eight mild herpes labialis events were recorded in the study, including outbreaks in participants already receiving antiviral prophylaxis. The paper reports treatment and subsequent prophylaxis for some participants but does not give a drug-and-dose prophylaxis regimen.

Clinical evidence · Documentation and expectations

Evaluate change after the series, not just after a session.

Physician-assessed outcomes [1]

Wrinkles, texture and laxity

Day 150 showed greater mean changes than Day 90.

At Day 150, mean improvement was 1.23 grades for global wrinkles (99% CI 1.11–1.34), 1.54 for texture (1.33–1.75) and 1.09 for laxity (0.93–1.26).

1.23 gradesglobal wrinkles
1.54 gradestexture
1.09 gradeslaxity
Interpret the statistics accurately

At Day 90, corresponding improvements were 0.93, 1.33 and 0.82 grades. At Day 150, the mean laxity improvement was not statistically greater than the one-grade target at the prespecified threshold (p=0.07). Improvement in laxity was observed in 97.9% and in texture in 100% at both follow-ups; this does not mean complete correction.

Measurement [1]

Combine grading, photographs and topography

Use the same outcome domains at baseline and follow-up.

The study used VISIA photographs and PRIMOS digital fringe projection of periorbital and mesolabial skin. PRIMOS assessed line roughness (Ra, Rmax, Rz) and surface roughness (Sa, Smax, Sz).

26% / 44%Sa reduction: periorbital / mesolabial
30% / 39%Ra reduction: periorbital / mesolabial
Keep endpoints distinct

These percentages are Day 150 changes in named PRIMOS parameters. They are not responder rates or overall rejuvenation percentages. Physician grading, instrumental measurements and patient experience should be reported separately; the paper does not provide a complete camera-positioning protocol.

Patient perspective [1]

Explain improvement without promising perfection

Patient-reported scores support a separate conversation about satisfaction with skin appearance.

At Day 150, 73% reported visible improvement in lines, wrinkles and texture, and 83% in pores. Mean self-rated improvement was 1.0 grade for lines/wrinkles, 1.1 for texture, 1.2 for pores and 0.8 for pigmentation.

73%visible lines/wrinkles and texture improvement
83%visible pore improvement
A balanced consultation message

Explain that the study evaluated a four-session course with a later review, that improvement varied by region, and that averages do not predict an individual result. This is a summary of the study findings, not a communication script tested in the trial.

Tolerability [1]

Include recovery and adverse events

No serious adverse incidents were recorded, but treatment was not event-free.

Nine mild device-related events were reported: eight herpes labialis outbreaks and one episode of excessively dry skin. Immediate physician-rated erythema was mild in 70% and moderate in 30%; none was severe.

5.2 / 10mean treatment pain
1.3 / 10mean treatment discomfort
What patients reported after treatment

Pain and discomfort used 0–10 scales. By the evening of Day 4, an average of 85% recorded no pain; by Day 6, 81% recorded no discomfort. No hyperpigmentation incidents were recorded. These findings do not justify a promise of painless treatment, zero downtime or zero risk.

Clinically documented outcomes · Illustrative cases

Visible skin changes. Carefully interpreted.

Before
After

Image for illustrative purposes only. Courtesy of amiea med.

Visibly Smoother Hands with Reduced Appearance of Fine Lines and Wrinkles

These before-and-after photographs show the appearance of the hands following medical mechanical microneedling. In the after image, the skin appears smoother, with less pronounced fine lines and wrinkles and a more even texture.

Before
After

Image for illustrative purposes only. Courtesy of amiea med.

Visibly Smoother Neck Skin with Reduced Appearance of Fine Lines and Wrinkles

These before-and-after photographs show the neck following medical mechanical microneedling. In the after image, fine lines and horizontal wrinkles appear less pronounced, while the skin looks smoother and more even in texture. Visible changes are individual and may vary with skin condition and treatment response.

Safety by design

Device features that support controlled facial treatment.

Smooth, controlled needle travel

The EXCEED platform combines high-frequency needle motion with contour-adaptive contact. This supports controlled handling across facial contours; the wrinkle trial did not isolate the clinical effect of the tilting plate. [1,4]

Low-displacement penetration

Six-needle geometry and concentrated drive are designed to limit skin displacement. This engineering rationale is relevant to controlled microinjury. [1,4]

Sterile, single-use cartridge

The study used six sterile, single-use needles. A disposable sterile cartridge supports a hygienic workflow when repeatedly treating facial skin; it does not remove the need for screening and aseptic technique. [1,4]

Dual anti-contamination protection

A safety membrane and protective sleeve help protect the handpiece from internal and external contamination. [4]

Adjustable depth for different facial zones

The 0–1.5 mm adjustment range accommodates the zone-specific ranges reported in the wrinkle study. [1,4]

Mechanical stimulation—without RF heat

Mechanical needling supplies no RF energy. Independent histological research supports collagen remodelling after mechanical microneedling. [2,4]

Scientific references and evidence scope

Safety and Effectiveness of an Automated Microneedling Device

[1] Primary source for all clinical assessment, treatment and outcome data above: Ablon G. Safety and Effectiveness of an Automated Microneedling Device in Improving the Signs of Aging Skin. Journal of Clinical and Aesthetic Dermatology. 2018;11(8):29–34. PMID: 30214664; PMCID: PMC6122507. Read the publication.

Minimally invasive facial rejuvenation

[2] El-Domyati M, Barakat M, Awad S, Medhat W, El-Fakahany H, Farag H. Multiple microneedling sessions for minimally invasive facial rejuvenation: an objective assessment. Int J Dermatol. 2015;54(12):1361–1369. doi:10.1111/ijd.12761. PubMed.

Micro-Needling Depth Penetration

[3] Sasaki GH. Micro-Needling Depth Penetration, Presence of Pigment Particles, and Fluorescein-Stained Platelets: Clinical Usage for Aesthetic Concerns. Aesthet Surg J. 2017;37(1):71–83. doi:10.1093/asj/sjw120. PubMed.

Exceed Unlimited Product Information

[4] amiea med. EXCEED UNLIMITED: product features and Safety by design. Device descriptions, warranty and worldwide platform figures are manufacturer information.

Bring evidence into your practice

Explore MEDICAL MICRONEEDLING

Discover the EXCEED family, arrange a product demonstration and explore professional education for your practice. Confirm the applicable indication and instructions for your market.

See Exceed Unlimited in Action

Download the Treatment Protocol for Free