EXCEED

UNLIMITED


MEDICAL MICRONEEDLING


Clinical evidence, German engineering and high-frequency performance in one professional platform—designed to support confident, consistent treatment.

Evidence

Dual FDA clearance

for facial wrinkles and facial acne scars

Clinically Proven

SEE DOCUMENTED outcomes

10-Year Full Warranty

Long-term investment protection

German Engineering

Built to exceptional standards

International platform

ISO 13485-Certified

quality management system

1,5M+treatments worldwide
12,000+medical providers
60+international markets
Since 2012medical needling expertise
Clinical evidence

FDA-cleared Exceed family. Backed by objective evaluation.

Wrinkles beforeBeforeWrinkles afterAfter

Image for illustrative purposes only.
Courtesy of amiea med

FDA-cleared · K233709

Facial wrinkles

Cleared in 2024 for facial wrinkles, following its predecessor—the first medical microneedling device with dual FDA clearance.

Clinical evidence for the Exceed platform comes from a study conducted with the predecessor Exceed, in which 48 subjects received four treatments approximately 30 days apart. At the Day 150 assessment, three blinded evaluators reported an improvement of at least one grade in:

85.4%glabellar frown
lines
87.5%periorbital lines
89.6%cheek folds
Patient selection and treatment areas

In the United States, EXCEED UNLIMITED is cleared for the treatment of wrinkles in adults aged 22 years or older with Fitzpatrick skin types I, II and/or III in the glabellar, periorbital and cheek-fold areas. In the underlying Exceed platform study, no subjects were graded as worsened in these three treatment areas.

BeforeAfter

Image for illustrative purposes only. Courtesy of Dr. Zoya Evsyukova,
specialist of regenerative medicine, plastic surgeon

FDA-cleared · K233709

Facial acne scars

Cleared in 2024 for improving the appearance of facial acne scars, building on the established Exceed microneedling platform with dual U.S. indications.

For facial acne scars, the Exceed platform was evaluated in a clinical study using the predecessor Exceed. Subjects received four treatments at four-week intervals and were assessed three months after the final treatment, with significant improvement observed irrespective of baseline acne-scar severity.

83%physician-assessed improvement
88%patient-reported improvement
88%would recommend treatment
Patient selection and study design

EXCEED UNLIMITED is FDA-cleared to improve the appearance of facial acne scars in adults aged 22 years or older with Fitzpatrick skin types I, II, III and IV. Fifty-nine percent achieved a one-grade improvement agreed upon by at least two of three blinded physicians.

Performance by design

Precision and power where clinical control begins.

Efficient depth
±0.15mm

Documented depth precision for strict protocol adherence.

FDA-documented depth precision supports consistent protocol-based treatment delivery and dependable clinical control.

Perpendicular penetration

Contour-adaptive contact for controlled vertical entry.

Penetration-depth accuracy of the Exceed platform was separately evaluated in porcine skin using high-speed-camera testing.

Stable motion

Uniform needle movement under demanding treatment conditions.

EXCEED demonstrated consistent high-frequency performance in a clinical study using an average 147.2 Hz frequency and 1.39 mm needle protrusion, with statistically significant positive outcomes.

147.2 Hzaverage treatment frequency
1.39 mmaverage needle protrusion
High-frequency performance
+25%

Up to 25% higher maximum frequency compared with leading professional medical mechanical microneedling systems.

Higher frequency for smoother, more efficient passes.

Rapid needle cycling supports smoother gliding with less tissue drag, helping maintain dense, even coverage while making each pass more efficient and supporting a more comfortable treatment experience.

150 Hzmaximum operating frequency
Balanced architecture
3.5×

More penetration power at every needle tip


EXCEED concentrates its drive across just 6 precision needles, delivering up to 3.5× higher calculated power per needle than leading medical microneedling devices. The result is stable penetration with less skin displacement and a very low “fakir effect”.

Safety by design

Safety by design

Smooth, controlled needle travel

High-frequency drive, precision geometry and a contour-adaptive plate support controlled entry and withdrawal.

Low-displacement penetration

High power per needle supports effective penetration while helping reduce unnecessary epidermal trauma.

Sterile, single-use cartridge

Each cartridge is supplied sterile and intended for one treatment, supporting hygienic clinical workflows.

Dual anti-contamination protection

An integrated safety membrane and protective sleeve help shield the handpiece from fluid ingress and external contamination.

Controlled depth within a tested envelope

Maximum needle penetration is limited to 1.5 mm when EXCEED UNLIMITED is used as intended.

Mechanical stimulation—without RF heat

EXCEED UNLIMITED delivers no RF energy or intentional heat into the skin.

Clinically documented outcomes

Measured change across scars, texture and skin structure.

Before
After

Image for illustrative purposes only. Courtesy of Dr. Zoya Evsyukova, specialist of regenerative medicine, plastic surgeon

Acne scars

High Acne-Scar Response Rate

[1] Acne-scarring studyFreiherr von Dalwig-Nolda D, Ablon G. Safety and Effectiveness of an Automated Microneedling Device in Improving Acne Scarring. Journal of Clinical and Aesthetic Dermatology. 2020;13(8):17–22. PMID: 33178377; PMCID: PMC7595357.

In the Exceed acne-scar study, 85.1% of subjects showed improvement after four treatments; mean needle protrusion was 1.39 mm and mean frequency 147.2 Hz.

Before
After

Image for illustrative purposes only. Courtesy of Dr. Zoya Evsyukova, specialist of regenerative medicine, plastic surgeon

Acne scars

Strongest Response in Rolling Scars

[1] Acne-scarring studyFreiherr von Dalwig-Nolda D, Ablon G. Safety and Effectiveness of an Automated Microneedling Device in Improving Acne Scarring. Journal of Clinical and Aesthetic Dermatology. 2020;13(8):17–22. PMID: 33178377; PMCID: PMC7595357.

Four treatments improved overall acne-scar severity by 0.91 grade, with rolling scars showing the greatest response at 1.06 grade.

Before
After

Image for illustrative purposes only. Courtesy of Dr. Dorota Kowalczyk, MD, specialist of aesthetic medicine.
With the use of exosomes from probiotic bacteria.

Texture

Facial Rhytide and Texture Improvement

[2] Ageing-skin studyAblon G. Safety and Effectiveness of an Automated Microneedling Device in Improving the Signs of Aging Skin. Journal of Clinical and Aesthetic Dermatology. 2018;11(8):29–34. PMID: 30214664; PMCID: PMC6122507.

Four treatments improved global wrinkle score by 1.23 grades and skin texture by 1.54 grades at Day 150.

Before
After

Image for illustrative purposes only. Courtesy of Dr. Dorota Kowalczyk, MD, specialist of aesthetic medicine.
With the use of exosomes from probiotic bacteria.

Texture

Ageing-Skin Laxity and Texture

[2] Ageing-skin studyAblon G. Safety and Effectiveness of an Automated Microneedling Device in Improving the Signs of Aging Skin. Journal of Clinical and Aesthetic Dermatology. 2018;11(8):29–34. PMID: 30214664; PMCID: PMC6122507.


Skin laxity improved in 97.9% and skin texture in 100% of subjects at Days 90 and 150.

Before
After

Image for illustrative purposes only. Courtesy of Dr. Zoya Evsyukova, specialist of regenerative medicine, plastic surgeon

Striae / OFF-LABEL

Objective Striae Remodelling

[3] Striae studyKampmann AC, Bender R, Busch K, Bauer C, Hettwer K, Aust M. Medical Microneedling for the Treatment of Striae Distensae: A Prospective Study Using the Exceed Medical Needling Pen. Aesthetic Medicine. 2026;12(2):18363. doi:10.57662/AM.2026.18363.

Objective measurements showed time-dependent remodelling of skin structure, smoothness and wrinkle depth, with significant effects emerging from Day 60.

Trusted by leading medical experts

What experienced clinicians value in EXCEED.

With EXCEED I’m able to work with exceptional precision and superior patient safety. Research-proven efficacy, outstanding German engineering and CE certification make it one of the most advanced microneedling technologies available. Its excellent results, minimal downtime and scar-free healing are essential to my patients.

PD. Dr. med. Matthias AustChief physician for plastic and aesthetic surgery · Germany

Safety and comfort should always be the highest priority in any medical procedure. In microneedling, equipment quality, medical certifications, power, precision and an optimal number of needles support proper penetration, even punctures, minimal epidermal trauma and shorter downtime.

Dr. med. Pejman BoorboorSpecialist in plastic and aesthetic surgery · Hannover, Germany

The products of amiea med represent a great advancement in the medical-aesthetic market. The small module head allows for precise work on acne scars in hard-to-reach areas that are poorly accessible with other devices. Each puncture induces controlled penetration to stimulate growth-factor release and resulting collagen production.

Dr. med. Sabine ZenkerDermatologist · Munich, Germany

There are so many things I love about EXCEED, but one in particular is the high level of patient experience it provides. Not only is it quiet, but it’s FDA-cleared and specifically designed to give a glowing complexion.

Sheila Nazarian MD, MMMBoard-certified plastic surgeon · Founder, Nazarian Plastic Surgery · Beverly Hills, USA
Bring evidence into your practice

See EXCEED UNLIMITED in action.

Request a tailored demonstration with a product specialist and explore protocols, training and commercial options for your market.

See Exceed Unlimited in Action

Download the Treatment Protocol for Free

Download the Treatment Protocol for Free

Download all available Treatment Protocols for Free